Integrated heating design. Auto standby function. Temperature lock function. Support and switchable. MCU controlled temperature calibration.
Features
Easy Temperature Setting Press “1 or 2 or 3” button to quickly preset temperature value; Long press “1 or 2 or 3” button ( more than 3 seconds ) to store temperature value.
Temperature lock function
Under the Loc menu, press “ ” and “ ” button to turn on/off. [1] [3] button to switch menus up and down, [2] button to exit and save settings.
C/F is available and exchangeable.
Temperature calibration Calibration range [-50 ~ 50 (-90 ~ 90 )]. When the real temperature is lower than the display temperature, the compensation takes a negative temperature value. When the real temperature is higher than the display temperature, take a positive temperature value.
Auto-sleep function Under the SLP menu, press “ ” and “ ” to set the sleep parameter Off/On. Sleep time: 10~60 minutes (default 10). The heating element temperature is 200 °C under sleep status. In sleep mode, pick up the soldering tool or press any key to automatically resume normal operation. (Note: If the device is not in a static state, it will affect the device to enter auto sleep.)
Automatically turn off the heating function Note: automatically turn off the heating function needs to be used when the auto-sleep function is turned on. When the auto-sleep function is turned off, the automatically turn off the heating function is turned off at the same time. The automatically turn off the heating function cannot be turned off when the auto sleep function is turned on.
Under the OFF menu, press“ ” and “ ” button can set the turn-off the heating time after sleep: 10~60 (default 20) minutes. When the heating state is turned off, pressing any button will automatically resume the normal working mode.
Beep alarm function available
Upper /lower temperature alarm function Under the H-L menu, press “ ” and “ ” button to set the upper /lower temperature values and OFF. It will alarm if soldering iron temperature higher or lower then the set alarm temperature. The upper and lower temperature rang is ±20 to 80 °C.
Password Protection Fault alarm function Display S-E is a sensor fault; H-E is a heater core fault
| Specifications | |
|---|---|
| Model | ST-965 |
| Power consumption | 65W |
| Input voltage | 110VAC/220VAC ±10% 50Hz/60Hz |
| Output voltage | 24VAC |
| Display method | LCD |
| Temperature range | 80 ~480 /176 ~896 |
| Temperature offset range | ±50 (±90 ) |
| Temperature stability | ±2 |
| Tip to ground resistance | <2Ω |
| Tip to ground potential | <2mV |
| Auto turn off the heating | 0~60 minutes (Default 10 minutes) |
| Dimensions | 210*88*150 mm |
| Net weight | 1.97kg |