Soldering

ST-862D-E High Power Hot Air Station with Fault Alarm Function

LCD display screen making control visualization.

Temperature unit switching function. Temperature locking, timed work function. MCU controlled temperature calibration, compensation for constant working. Strong air volume with brushless fan. Easy to replace with pluggable heater. Convertible with straight air and spiral air. Auto-sleep function. Fault Alarm Function,the warning light will sound and flash to indicate when there is a fault.

Features

Easy Temperature Setting Press air “up” or “down” key to adjust the air volume and temperature. Long press for quickly adjusting. Stop pressing the key for 3 seconds, it will save the setting automatically.

The cool air function is used when the temperature setting value under 100 0C

Saving and Call Shortcut Temperature Press button “1”/ “2”/ “3” to call or save preset temperature and air flow value.

Temperature Lock Function Under Menu Loc, it can turn on or off temperature lock function by pressing “UP” or “DOWN” key; then press Button “2” to exit and save your setting.

0C/0F available In menu C-F mode, it can switch temperature unit / by pressing “UP” or “DOWN” key.

Temperature Calibration Under menu CAL mode, press “UP”or“DOWN” key to enable temperature calibration function, which calibration range is -500C~ 500C(-900F~900F). Calibration value will be negative as actual-measured temperature is lower than setting temperature; Calibration value will be positive as actual-measured temperature is higher than setting temperature.

Beeping function Under menu BL mode, it can turn on/ off the beeping function by pressing “UP” or “DOWN”key

Timing function Under menu HTO mode, it can adjust time of timing function by pressing “UP” or “DOWN” key. Time range from 10 to 900 seconds

Standby Function In menu STBY, press “UP” or “DOWN” can adjust standby function on or off. It can adjust the standby time from 1 to 10mins. When standby function is on, this handle can be shut off automatically when putting it on this holder. If within standby time, taking this handle out of holder it will recover to work; if beyond the standby time, it won't work until pressing the button on hot air gun. (Note: if both timing function and standby function are on simultaneously, timing function will be recount time when the hot air gun working. )

Fault alarm function
E2 Sensor open circuit — Poor contact of air gun connector or handle. Replace the heater.
E3 No signal of zero-cross — The zero-cross circuit is damaged and needs repair.
E7 Sensor short circuit — A short circuit occurred in the temperature sensor or the heating core is open. Replace the heating element.
E8 Over temperature protection:
1. Temperature sensor abnormal — replace the heating core.
2. Heating core temperature too high — allow it to cool, then restart the machine.
E10 Heater overheating — Needs repair.
E11 Fan broken — Needs repair.
E13 Heating output switch component failed — Needs repair.
Specifications
ModelST-862D-E
Power Consumption1000W (MAX)
Input Voltage110VAC/220VAC ±10% 50Hz/60Hz optional
Temperature Range100–480°C / 212–896°F
Setting Range of Volume1–99%
Air Flow20–120 L/min
Standby Heater Cooling FunctionSupport
Beeping FunctionAvailable
Standby FunctionAvailable
Timing FunctionAvailable
Shortcut Temperature / Air Flow3 sets shortcut temperatures / air flow for quick selection
Temperature Calibration±50°C / ±90°F
Temperature Adjustment10 digits (Coarse) / 1 digit (Fine-tuning)
Air Flow Adjustment2 digits (Coarse) / 1 digit (Fine-tuning)
Working ConditionsTemperature 0–40°C, relative humidity <80%
Storage ConditionsTemperature -20–80°C, relative humidity <80%
Auto-Sleep FunctionAvailable
Dimensions21 × 17.4 × 15 cm
Net Weight3.34 kg