GT-8100A Intelligent Hot Air Station

Big TFT color screen, more convenient to set and monitor parameters.

1300W pluggable ceramic heater,heating fast. Built-in brushless fan, long service life and low noise. PID algorithm temperature control, accurate and stable temperature. Infrared temperature calibration function. Temperature curve setting function. 3 sets shortcut air volume/temperature to simplify operations. Support control the switch on and off of the smoke purifier. Can be controlled by external pedal. With RS485 communication interface, support IoT function.

Features

Language Setting Press “UP” or “DOWN” button to switch between Chinese and English.

Parameter Lock Press “UP” or “DOWN” button to switch (unlock, locked 1, locked 2) parameter.

Temperature Unit Press “UP” or “DOWN” button to switch between / temperature unit.

Temperature Compensation Short press “UP” or “DOWN” button to reduce or increase parameter in one unit; Long press “ ” or “ ” button to rapidly reduce or increase parameter.

Buzzer Function Press “UP” or “DOWN” button to open or close the buzzer.

Foot Switch Mode

Press “UP” or “DOWN” button to switch between foot switch jog and continue mode. In jog mode: Auto-heating mode is invalid. In continue mode: Timing setting is invalid. (Note: When using an external foot switch, only the foot switch can control the heat gun to work)

Heating Mode

Press “UP” or “DOWN” button to switch between automatically and manually heating mode. (Only valid in the text interface, and it's automatically by default) In automatically mode: When the hot air gun is placed on the handle bracket, the hot air gun does not blow air, and pick up the hot air gun again, it will resume to work. In manually mode: Control the hot air gun to start/stop operation by the button on the hot air gun handle.

Cool Air Function

Password Setting In the password setting interface, press “2” or “MENU/ENTER” button to enter the password setting interface.

Factory Reset In the factory reset interface, press “2” or “MENU/ENTER” button to enter the factory reset interface.

IR Temperature Calibration Function In the text working interface, press “MENU/ENTER” + “3” button to turn on/off the IR temperature calibration function.

Specifications
Rated Operating Voltage AC 230V ±10% 50Hz / (110V ±10% 60Hz)
Power 1330W (220–240V~) / 1000W (110–120V~)
Fuse T8A (AC 250V) / T12A (AC 125V)
Temperature Range 100°C ~ 500°C / 212°F ~ 932°F
Air Volume Range 1% ~ 100%
Timing Time 10 ~ 900s (Can be turned off)
Temperature Unit °C / °F (default °C)
Air Flow 120 L / Min (Max)
Alarm and Protection Functions Heater open circuit alarm, sensor fault alarm, zero crossing signal alarm,
SCR damage alarm, over-temperature protection alarm
Password Protection Function Available (Off by default)
Alarm Function Available (On by default)
User Temperature Compensation ±50°C / ±90°F
Language Chinese / English
Heating Power Display 5 dynamic power bars
Temperature Adjustment Step Long press: 10-unit adjustment
Short press: 1-unit adjustment
Air Volume Adjustment Step Long press: 2-unit adjustment
Short press: 1-unit adjustment
Rapid Temperature / Air Volume / Time 3 groups of temperature, air volume, and time settings for quick recall
Working Conditions Temperature: 0°C ~ 40°C
Relative Humidity: <85% RH
Dimensions 230 (L) × 142 (W) × 145 (H) mm
Weight (Net Weight) Approx. 3.5 kg